061 - Glazing in fire with Yu Wang episode artwork

EPISODE · Aug 2, 2022 · 47 MIN

061 - Glazing in fire with Yu Wang

from Fire Science Show · host Wojciech Wegrzynski

The relation between ventilation conditions and fire severity is quite a fundamental one. You don't even have to be a fire safety engineer to realize that more air means a bigger fire. But how does air get into the compartment fire in the first place?Through broken windows of course!And here we come to the subject of today's episode. Because with all the considerable improvements in glazing technologies for building facades, is it really okay to assume that the glazing has failed and all we are left is a giant hole that allows the air flow inside? How does the glass fail, and when and what exactly are the consequences of this failure? These are the questions asked to professor Wang Yu of the State Key Laboratory of Fire Science (SKLFS) at USTC, China. Yu takes me through his research from his PhD at Edinburgh, and through more recent experiments carried out by his group in China. We discuss FEM modelling of glass and some specific behaviour of modern glazing technologies exposed to different kinds of fires.If you would like to learn more about this fundamental topic, here are some great further reading resources (Yu has so far 29 papers on this subject and these are just the tip of the iceberg!):Experimental study on fallout behaviour of tempered glass façades with different frame insulation conditions in an enclosure fireInvestigation of the thermal response and breakage mechanism of point-supported glass facade under wind loadDetermination of critical fallout condition of tempered glass in an enclosure fireThe effect of glass panel dimension on the fire response of glass façadesCrack evolution process of window glass under radiant heatingDetermination of critical breakage conditions for double glazing in fire----The Fire Science Show is produced by the Fire Science Media in collaboration with OFR Consultants. Thank you to the podcast sponsor for their continuous support towards our mission.

Episode metadata supplied by the publisher feed · Published Aug 2, 2022

Embed this episode

The relation between ventilation conditions and fire severity is quite a fundamental one. You don't even have to be a fire safety engineer to realize that more air means a bigger fire. But how does air get into the compartment fire in the first place? Through broken windows of course! And here we come to the subject of today's episode. Because with all the considerable improvements in glazing technologies for building facades, is it really okay to assume that the glazing has failed and all ...

Distinct summary based on available episode metadata or transcript content.

NOW PLAYING

061 - Glazing in fire with Yu Wang

0:00 47:59

No transcript for this episode yet

We transcribe on demand. Request one and we'll notify you when it's ready — usually under 10 minutes.

No similar episodes found.

No similar podcasts found.

Frequently Asked Questions

How long is this episode of Fire Science Show?

This episode is 47 minutes long.

When was this Fire Science Show episode published?

This episode was published on August 2, 2022.

Is there a transcript available for this episode?

Yes, a full transcript is available for this episode. You can read the complete transcript on the episode page.

Can I download this Fire Science Show episode?

Yes. Use the download control on the episode player to save the publisher-provided media file.
URL copied to clipboard!