255 - Timber load bearing capacity in fire from nano- to megascale with Felix Wiesner episode artwork

EPISODE · Jun 10, 2026 · 1H

255 - Timber load bearing capacity in fire from nano- to megascale with Felix Wiesner

from Fire Science Show · host Wojciech Węgrzyński

A timber column can survive the heating phase of a fire resistance test and still collapse later, after the flames are gone. We know there is so much more to structures in fires than the test demonstrates, but how much exactly do we know about timber nowadays? In this episode we try to dive deeper and discuss mass timber fire safety, structural fire engineering, and what a fire resistance rating does and does not tell us. I’m joined by Dr. Felix Wiesner from the University of British Columbia, this year’s IAFSS Proulx Award recipient, to unpack his review on mass timber load-bearing capacity in fire across scales. We start where most design decisions begin: full-scale furnace tests and the practical reality that many modern timber elements are too large, too new, or too costly to test under load. From there we dig into the reduced cross-section method, charring rate assumptions, and the controversial “zero-strength layer” that turns heated wood into a simplified design allowance, even as uncertainty and code-to-code differences persist. Then we turn to the decay phase and delayed failure, connecting recent column results to the bigger question of performance-based design for compartment fires that heat and cool. To model that behaviour, we need credible links between temperature, strength reduction, and elastic modulus reduction, and we need to care about how the data were generated: steady-state oven tests versus transient tests where timber is loaded first and heated with steep gradients. Finally, we go down to the microscale and nanoscale, where moisture migration and even hydrogen-bond changes in cellulose help explain why “loaded while heating and cooling” can permanently reshape capacity. If you work with mass timber buildings, timber fire design, Eurocode approaches, or structural safety in fire, this is a deep reset on what matters most. Read about the IAFSS Awards here https://www.iafss2026.com/awardsRead the whole paper with a more in-depth view on the subject "From nano-to megastructure: A review of mass timber load-bearing capacity in fire"----The Fire Science Show is produced by the Fire Science Media in collaboration with OFR Consultants. Thank you to the podcast sponsor for their continuous support towards our mission.

Episode metadata supplied by the publisher feed · Published Jun 10, 2026

Embed this episode

A timber column can survive the heating phase of a fire resistance test and still collapse later, after the flames are gone. We know there is so much more to structures in fires than the test demonstrates, but how much exactly do we know about timber nowadays? In this episode we try to dive deeper and discuss mass timber fire safety, structural fire engineering, and what a fire resistance rating does and does not tell us. I’m joined by Dr. Felix Wiesner from the University of British C...

Distinct summary based on available episode metadata or transcript content.

NOW PLAYING

255 - Timber load bearing capacity in fire from nano- to megascale with Felix Wiesner

0:00 1:00:57

No transcript for this episode yet

We transcribe on demand. Request one and we'll notify you when it's ready — usually under 10 minutes.

No similar episodes found.

No similar podcasts found.

Frequently Asked Questions

How long is this episode of Fire Science Show?

This episode is 1 hour and 0 minutes long.

When was this Fire Science Show episode published?

This episode was published on June 10, 2026.

Can I download this Fire Science Show episode?

Yes. Use the download control on the episode player to save the publisher-provided media file.
URL copied to clipboard!