Danfoss ERC213 Parameters Review episode artwork

EPISODE · Jun 27, 2018 · 1H 14M

Danfoss ERC213 Parameters Review

from HVAC School - For Techs, By Techs

In today's podcast episode, Jonathan Romberg comes on to discuss how the Danfoss ERC 213 works and reviews its parameters with us. Timestamps: 10:30 – Key Features 10:41 – Voltage Protection 10:56 – Compressor Protection 14:43 – Applications 15:15 – App 0 No predefined application 15:28 – App 1 Medium temperature ventilated refrigeration units with timed natural defrost 15:52 – App 2 Medium temperature ventilated refrigeration units with timed electrical defrost 16:03 – App 3 Low temperature ventilated refrigeration units with timed electrical defrost 16:13 – App 4 Medium temperature ventilated refrigeration units with electrical defrost (by temperature) 16:26 – App 5 Low temperature ventilated refrigeration units with electrical defrost (by temperature) 16:37 – App 6 No predefined application with a simplified list of parameters 19:45 – Sensors 22:06 – Basic Groups of Parameters 23:09 – r-- Thermostat 23:12 – r00 Temperature setpoint 23:24 – r01 Differential 23:32 – r02 Min setpoint limitation and r03 Max setpoint limitation 24:02 – r04 Display offset 25:19 – r05 Display Unit (°C/°F) 25:33 – r09 Calibration of Sair 25:47 – r12 Main switch 27:17 – r13 Night set back 27:48 – r40 Thermostat reference displacement (offset temperature) 28:30 – r96 Pull-down duration and r97 Pull-down limit temperature 29:06 – A-- Alarms 29:13 – A03 Delay for temperature alarm during normal conditions 30:15 – A12 Delay for temperature alarm during pull-down/start-up/defrost 31:00 – A13 High-temperature alarm limit (Cabinet/Room) 31:34 – A14 Low-temperature alarm limit 31:55 – A27 DI1 delay and A28 DI2 delay 32:17 – A37 Condenser high alarm limit 32:41 – A54 Condenser high block limit 33:45 – A72 Voltage protection enable 34:03 – A73 Minimum cut-in voltage and A74 Minimum cut-out voltage 35:04 – A75 Maximum Voltage 37:37 – d-- Defrost 37:49 – d01 Defrost method 38:32 – d02 Defrost stop temperature 38:50 – d10 Defrost stop sensor 40:51 – d03 Defrost interval 41:16 – d04 Max defrost time 43:38 – d05 Defrost delay at power up (or DI signal) 44:29 – d06 Drip delay 44:49 – d07 Fan delay after defrost 45:49 – d08 Fan start temperature after defrost 47:21 – d09 Fan during defrost 47:40 – d10 Defrost stop sensor (part II) 48:16 – d18 Compressor accumulated runtime to start defrost 50:04 – d19 Defrost on demand 53:26 – d30 Defrost delay after pull-down 53:53 – F-- Fan control 54:03 – F01 Fan at compressor cutout 55:00 – F04 Fan stop evaporator temperature 55:51 – F07 Fan ON cycle and F08 Fan OFF cycle 56:28 – c-- Compressor 56:37 – c01 Compressor minimum ON time 56:47 – c02 Compressor minimum OFF time 57:01 – c04 Compressor OFF delay at door open 57:51 – c70 Zero crossing selection 58:22 – o-- Others 58:37 – o01 Delay of outputs at startup 59:11 – o02 DI1 configuration 1:01:36 – o05 Password 1:02:08 – o06 Sensor type selection 1:02:27 – 015 Display resolution 1:03:31 – o23 Relay 1 counter, o24 Relay 2 counter, and 025 o24 Relay 3 counter 1:04:13 – o37 DI2 configuration 1:04:52 – o61 DI2 configuration 1:05:07 – o67 Save settings as factory 1:05:39 – o71 DO2 config 1:06:23 – o91 Display at defrost 1:07:04 – P-- Polarity 1:07:06 – P73 DI1 input polarity and P74 DI2 input polarity 1:07:32 – P75 Invert alarm relay 1:07:59 – P76 Keyboard lock enable 1:08:21 – u-- Readouts 1:08:30 – u00 Controller Status 1:09:37 – u01 Air temperature (Sair) 1:10:12 – u58 Compressor relay status, u59 Fan relay status, u60 Defrost relay status, and u63 Light relay status   Find out more about the Danfoss ERC 213 HERE. Learn more about Refrigeration Technologies at refrigtech.com. If you have an iPhone, subscribe to the podcast HERE, and if you have an Android phone, subscribe HERE.

Episode metadata supplied by the publisher feed · Published Jun 27, 2018

NOW PLAYING

Danfoss ERC213 Parameters Review

0:00 1:14:35

No transcript for this episode yet

We transcribe on demand. Request one and we'll notify you when it's ready — usually under 10 minutes.

MG Show MG Show The MG Show, hosted by Jeffrey Pedersen and Shannon Townsend, is a leading alternative media platform dedicated to uncovering the truth behind today’s most pressing political issues. Launched in 2019, the show has grown exponentially, offering unfiltered insights, comprehensive research, and real-time analysis. With a commitment to independent journalism and factual integrity, the MG Show empowers its audience with knowledge and encourages active participation in the political discourse. French Your Way Jessica: Native French teacher founder of French Your Way Boost your French listening skills and test your comprehension with this one of a kind series of podcasts. Get the chance to listen to a real conversation between native speakers talking at normal speed AND customise your learning experience through carefully designed sets of questions (2 levels of difficulty) available for download at www.frenchvoicespodcast.com. All interviews also come with the transcript. French teacher Jessica interviews native speakers of French from around the world who share a bit of their life and passion. Where else would you meet in one same place a French yoga teacher based in Melbourne, a soap manufacturer from Provence, or a couple cycling around the world? That Hoarder: Overcome Compulsive Hoarding That Hoarder Hoarding disorder is stigmatised and people who hoard feel vast amounts of shame. This podcast began life as an audio diary, an anonymous outlet for somebody with this weird condition. That Hoarder speaks about her experiences living with compulsive hoarding, she interviews therapists, academics, researchers, children of hoarders, professional organisers and influencers, and she shares insight and tips for others with the problem. Listened to by people who hoard as well as those who love them and those who work with them, Overcome Compulsive Hoarding with That Hoarder aims to shatter the stigma, share the truth and speak openly and honestly to improve lives. Flottengeflüster ALD Automotive Österreich | LeasePlan Beim Flottengeflüster powered by ALD Automotive | LeasePlan präsentieren Jörg Janik und Peter Gutenbrunner alle zwei Wochen spannende Informationen rund um das Thema nachhaltige Mobilität. Beide beschäftigen sich schon lange mit der Thematik und bringen umfangreiches Fachwissen mit. Sollten sie aber doch einmal nicht weiter wissen, werden unsere Expert*innen hinzugezogen, die ihnen gerne mit Rat und Tat zur Seite stehen.

Frequently Asked Questions

How long is this episode of HVAC School - For Techs, By Techs?

This episode is 1 hour and 14 minutes long.

When was this HVAC School - For Techs, By Techs episode published?

This episode was published on June 27, 2018.

What is this episode about?

In today's podcast episode, Jonathan Romberg comes on to discuss how the Danfoss ERC 213 works and reviews its parameters with us. Timestamps: 10:30 – Key Features 10:41 – Voltage Protection 10:56 – Compressor Protection 14:43 – Applications 15:15 –...

Can I download this HVAC School - For Techs, By Techs episode?

Yes, you can download this episode by clicking the download button on the episode player, or subscribe to the podcast in your preferred podcast app for automatic downloads.