EPISODE · Apr 14, 2026 · 36 MIN
EEVblog 1744 - NEW Micsig DP700 High Voltage Differential Probe
from EEVblog on Odysee · host EEVblog
The DP700 is Micsig's third suck of the sav on a high voltage differential probe. Not to be confused with the MDP700 which this replaces.https://www.micsig.com/DPA/00:00 - Comparison to the DP10007 and MDP70003:58 - Unboxing of the DP70005:52 - CMRR measurement hardware setup09:52 - Sanity check gain and bandwidth check.11:29 - Zero function12:25 - Measuring the CMRR16:30 - Trap for young players. RMS vs AC RMS, it's all in the sigma17:44 - Another trap for young players, double sigma19:07 - CMRR at 100MHz22:41 - Real world test on a 100V GaN MOSFET25:28 - Teardown29:44 - PCB inspectionRelated videos: Reverse Engineering the DP10007: https://www.youtube.com/watch?v=GOk1BYKSsOICMRR: https://www.youtube.com/watch?v=vDe_BHvRpksGaN testing and Optical Fiber probe: https://www.youtube.com/watch?v=qgZgSDqmVMgWeb Site: http://www.eevblog.comHardware Store: https://eevblog.store/Merch Store: https://eevblog.dashery.com/If you find my videos useful you may consider supporting the EEVblog on Patreon: http://www.patreon.com/eevblogOther channels:EEVblog2: http://www.youtube.com/EEVblog2EEVdiscover: https://www.youtube.com/eevdiscover#ElectronicsCreators #Micsig...https://www.youtube.com/watch?v=0xqt4WF2G7k