Welcome to the PIPELINERS podcast, Episode 148, sponsored by Burns McDonald, delivering pipeline projects with an integrated construction and design mindset, connecting all the elements, design, procurement, sequencing at the site. Burns McDonald uses its vast knowledge, the latest technology and ownership commitment to safely deliver innovative quality projects. Learn how Burns McDonald is on site through it all at BurnsMCD.com. The PIPELINERS podcast, where professionals, public needs and industry insiders share their knowledge and experience about technology, projects, and pipeline operations.
And now your host, Russell Treet. Thanks for listening to the PIPELINERS podcast. I appreciate you taking the time and to show the appreciation we give away a customized Yeti Tumbler, the one listener each episode. This week, our winner is Dyer Schlitzkas with LGA engineering.
Dyer, if I got your name wrong, but got close, I should get credit because it is a tongue twister, my friend. Anyway, congratulations. To learn how you can win this signature prize back, stick around at the end of the episode. This week, Frank O'Nesto with Burns McDonald is going to join us.
And I'm going to get educated about alternating current effects and mitigation with pipelines. Frank, welcome to the PIPELINERS podcast. Afternoon, Russell. Thanks for having me.
Really a pleasure. I've got it. I've got to tell the listeners right up front that I've asked you to come in and talk about alternating current effect on pipelines and mitigation. And I'm just going to confess, I know very little about this.
So the quality of my questions in this episode may be suspect. That's my disclaimer. Well, that's all right, Russell, because, you know, the industry as a whole still has a lot to learn about the exact mechanisms of a senior fairness. There's been countless studies done throughout the 19th century and 20th century documenting the impacts that alternating current power lines can have on pipelines.
And a lot of these studies conflict. There's a lot of gaps in some of the information. So like I said, our industry has a whole still has a lot to learn. Well, look, why don't you give us a little bit about your background, your education and how you got into the pipeline and how you have developed your expertise around AC effect?
Sure. So I actually studied mechanical engineering at Marquette University and I was interested in manufacturing and metalworking. And that led me to have a brief career in tool and dye engineering, specifically related to foundries and other machining processes. And through doing that type of work, I had some metallurgy experience, UT testing experience.
And I was approached by a pipeline designer who saw my metallurgy and UT testing experience and thought it would be a good fit in the corrosion world. And that's really how I got started in pipeline corrosion mitigation. And from day one, I was heavily involved in AC interference, modeling and mitigation design. And it's a subject that I find absolutely fascinating, particularly because there's still a lot we have to learn.
Well, you know, and I think I always think it's interesting to have when you talk to engineers that it generally takes five to 10 years from the time you start working as an engineer before you land in that discipline that for some reason, you just find compelling. Yeah, definitely. And generally, it's some strange combination of factors. That seems to be thematic.
At least it is in my, it is in my career. I mean, I grew up a civil engineer and I did construction long enough to know that that what I wanted to do. Right. Yeah, I'll admit, I didn't know corrosion engineering was a thing when I was in school.
Neither did I. Mechanical engineering is one of those things that nearly caused me to not be an engineer. Right. I feel you.
So you came into pipelining through the metal, basically. Right. Yep, through metalworking industry. So why don't we talk a little bit about just in general, you can educate me.
How does alternating a current affect a pipeline? Sure. So a lot of these impacts have emerged in recent years for a couple of reasons. It's very common nowadays to co-locate a pipeline in the same right away as a high voltage transmission line.
You know, it's a very attractive option from a cost perspective, land acquisition. Sometimes the utility owns both the high voltage transmission and the pipeline and land is becoming scarce. So routing these structures in the same corridor makes sense. But unfortunately it has resulted in some of the AC interference concerns that we see nowadays.
Another reason why in recent years, AC interference has become so prevalent is because of the improvement in our pipeline coating qualities. The the co-lanes that we use nowadays, like fusion bonded epoxy are far superior to the older coatings that we use to use like coal tar. And as a result, this high coating quality is not allowing alternating current to naturally dissipate off the pipeline because of the absence of small coating imperfections. So, you know, an old coal tar coating had a lot of micro imperfections.
And so there were areas along the length of the pipe where steel wasn't contact with the earth. And when these pipelines were in close proximity to power lines, that current would get out of the pipeline. But just as quickly as it got on, it would naturally dissipate off of the pipeline. But now with these modern fusion bonded epoxy coatings and other coatings, that current has nowhere to go.
And it's so it's being retained by the pipeline and it's it's leading to accelerated corrosion and elevated voltage levels, which are a safety concern. So I want to unpack that a little bit because I did a I did a podcast a while back on corrosion and the fact that that's an electrochemical process. And we talked about holidays and such. So that was that was good because I knew that I needed to know about corrosion.
I knew nothing about corrosion. So if I'm hearing you correctly, when we're trying to restate, what I think I heard you say, that because the coatings are so effective of isolating the metal from the soil, the AC current that gets collected gets concentrated. That's exactly fair way to say it. Yep.
That's exactly right. Interesting. So you know, the benefit that these modern coatings provide from a cathodic protection standpoint and a general corrosion mitigation standpoint, those benefits far outweigh the negative impact of alternating current. It's it's unfortunate that it has led to these alternating current concerns.
But like I said, because the benefit outweighs those concerns, we have turned to mitigating the AC interference effect rather than, you know, not not going to go backwards in terms of what we're doing with coding. Exactly. We're not going to have guys out with coal tar and brushes, you know, paint the pipeline before we drop it the ditch. Exactly.
Yeah. So it raises a question for me, though, that, you know, how what's the mechanism? So how does that electric current get captured in the metal? What's the mechanism that causes that to occur?
Sure. So there's actually three mechanisms of AC interference phenomena that we observe. I'll start off with the first one, which is capacitive coupling. That generally occurs during pipeline construction when you have ungrounded segments of pipe resting on wooden skids before they're lowered into the trench.
And when these ungrounded segments of pipe are in close proximity to a high voltage line, they're going to act as a capacitor. You know, they're ungrounded. We have an alternating current source and close proximity, the air between those pipelines and the conductors that could be treated as a dielectric medium and then your, your pipeline is the capacitor plate. And those ungrounded segments of pipe are going to start collecting AC charge.
And it can lead to a rise in AC voltage, which could become a shock hazard to construction workers. So that's why it's very common to you see a contractor usually ground the ends of these skidded pipes to reduce capacitive coupling. And once the pipeline is installed in backfield, the capacitive effect is no longer concerned because the pipeline is grounded. So I want to ask a couple of questions about that because a couple of things come up.
There's a place where there's metal contact, contact to earth. If the pipeline is perfectly isolated, it's not grounded. Is that correct? Yeah.
Correct. And no coating is perfect. So when that pipe is backfield, there are still places along that pipeline where there's microscopic pinholes, metal in contact with the earth. At some point in the future, somebody's going to come up with a perfect coating and then this is going to become a bigger problem.
Yeah, no, no, no, no, no real problem. You're anticipating the future. The other question I want to ask. So nowadays, you know, we recharge our iPhones and such by setting them on these fancy little pads and we don't actually have to plug something in.
Are we effectively doing the same thing, this, this capacitive adduction to charge our iPhones? It's yeah, you could think of it as a similar concept. And actually, that's kind of going to lead me into the next interference mechanism, which is inductive coupling. And when we talk about this, we could think about, you know, what you just said, or like an induction cooktop.
And what's going on here is that now the pipeline is backfield and grounded. It's still existing within that electromagnetic field. And Faraday's law of induction says that when you insert a parallel metallic conductor into an electromagnetic field, you can induce a voltage onto that parallel conductor. That's actually how transformers work.
You have two sides of a transformer, the primary and the secondary coils. One of those sides might be larger than the other, but you induce a voltage across those coils to either step up or step down voltage. And that's how you can think of the system that we're observing here. It's a very poor transformer.
Right. Right. And what's the third mechanism? So that third mechanism of interference is called resistive coupling, otherwise known as conductive coupling.
And that occurs during a power line fault scenario. So just like pipeline operators have overpressure events on our systems, transmission line high voltage transmission line operators, they have fault events on their pipeline or their high voltage lines. And that could be a result of a lightning strike, high winds, maybe, you know, in the worst case scenario, a tower has has fallen and made contact with the earth. But either way, there is unintended current flowing to ground from those transmission line conductors flowing through the tower grounds into the earth.
And because it's in close proximity to the pipeline, it's going to use the soil as a direct path to couple with that pipeline. So we have these large currents injected into the earth. That current is looking for a path of least resistance and it sees this nice pipeline, steals very low resistance and it's going to jump on there. I mean, that'd be similar to a lightning strike.
Yeah, exactly. Exactly. Right. And with with inductive coupling or resistive coupling, where that current jumps off of the pipeline and returns to its source, that's where we observe accelerated corrosion.
And we measure that discharge of current in the units of ampere meter squared, that's current density. So a couple other questions and these may be nonsensical. I don't know. But does the voltage that the high tension lines are carrying?
Does it matter? I mean, does higher voltage cause more of this problem? Or is that is it more about current? It is entirely dependent on current.
So, you know, you could have a 345 kilovolt power line operating at 500 amps. It could operate at 1000 amps, 1500 amps, whatever it may be. So that's why the actual voltage rating of the power line doesn't provide enough insight to determine if it's going to cause risk to our pipelines or not. We really have to take a look at the steady state currents that are flowing through those conductors, emergency currents, and those fault currents.
And does it matter if that current is cycling up and down? Yes, it does. That that has multiple impacts, particularly to some of the corrosion mechanisms that are occurring at the steel to soil interface. If the current is cycling up and down, then the induced voltage on the pipeline is going to cycle up and down.
And that's going to cause difficulties for the cathodic protection because they're more designed to operate at a constant voltage. Right. Right. Exactly.
Yeah. Yeah. You you took that as a question, not a state. Yeah, that constant cycling, you know, we operate power lines at 60 hertz in Europe, that use 50 hertz, but that constant cycling does have an impact on the overall magnitude of interference and then also how it impacts some of the cathodic protection levels and the performance of our CP systems.
Interesting. So, you know, this is all awesome. I want to ask a couple of more just kind of, you know, what is the problem we're trying to deal with questions and the next one is more around. So if I have a pipeline and I it's running in a, you know, a high tension transmission line for people that don't know what high tension means, that's just basically the tall electrical towers calling carrying the big fat cables that are carrying a lot of voltage.
So when those things, when those pipelines are moving down that, that right of way, there's one impact. But what happens when it moves out of the right away? Great question. Yes.
So we define that paralleling length as co-location. So when these two structures are paralleling or near parallel, we call that a co-location and we generally consider everything within 2,500 feet to be co-located with these transmission lines. And so, you know, that plays into the magnitude of interference, but let's say these two routes are parallel and all of a sudden the pipeline diverges away from that power line right away. At that point of divergence, we generally observe a spike in interference.
And that has to do with the pipeline orientation, changing in relation to the magnetic field. That disruption of the magnetic field causes a spike in voltage. Right. Yeah.
And I'm the electrical engineering is one of the other reasons I didn't nearly didn't make it out of engineering school. I did very well in structural engineering just for the record. I did very well in math. But sure.
Just so that the listeners know that I wasn't a complete embecile on college. Well, I might have been a complete embecile on college, but not for those reasons. Like I said, I studied mechanical engineering. So, you know, the two things I studied the least were chemistry and electricity.
So it's ironic that I'm having this conversation with you today. Yeah, exactly. I think that's also thematic with engineers as well. Right.
So the other question I want to ask is, to what degree does proximity from the pipeline to the power source matter? It matters a lot. There's there's studies that show that pipelines can experience significant interference when that separation distance is in excess of a thousand feet. So even if you're a good distance away from the power line, that power line still has the ability to induce current onto the pipeline.
So that's why I said earlier, we consider everything within 2,500 feet to be co-located with the power line. Obviously, the farther you are away, the lower the risk. But generally we consider everything within 100 feet to be at a high risk for AC interference. And of course, that's dependent on dozens of other variables.
Yeah. We can't just look at one or two and then get an idea of how these transmission lines are going to impact our pipeline. We got to look at all the variables and they paint a whole picture of, you know, the exact interference. That's right.
Cause they all interact and they all they all they all they all have, you know, managing one has implications for the other. Right. Right. For the risk standpoint.
Sure. So, it does it matter if you've got other pipelines in the right way, does that have any impact? It has some impact. I wouldn't say it is the most influential of variables.
But if you have, you know, if you have an electromagnetic field and you insert one parallel metale conductor in there, that metale conductor is going to absorb some of that field. And then the more and more conductors you insert into the field, they're each going to absorb a little bit of the field. So it does have an impact. But I would say that it's more difficult to observe how that would impact the overall magnitude of interference.
What about another pipeline that's crossing over your pipeline? You know, you're in the right way with the high tension lines and you've got a line that's crossing over you. Does that what impact would that have? Cause that's going to, that's going to modify the field for sure.
Sure. Yeah. So at a crossing location, I mean, let's say that you have one pipeline that has a severe, a senior, fairance concern and you have a second pipeline crossing that there is the chance for interference between those two structures. So especially if the structures are bonded, you know, in the cathodic protection world, we, we bond a lot of structures to maybe protect multiple pipelines with one system or to mitigate DC interference between cathodic protection systems.
So if these two lines crossed, especially if they bonded, they have the ability to influence each other. And that second pipeline could potentially pick up some of that harmful AC influence. Now it's, it's actually interesting if we're talking about pipeline crossing transmission line, if those two structures cross it in 90 degrees, induction actually is not possible. And it ties back to paralleling length.
You need that paralleling length to induce a voltage or current onto that pipeline. And when these two structures are crossing at 90 degrees, there is no paralleling length and induction is no longer possible. So when we're talking about crossing angles, we always recommend that pipeline operators or if it's a new transmission line being constructed, we always recommend that these structures try to cross as close to 90 degrees as possible. Interesting.
It makes sense. But now I'm now starting to think about, well, does it matter if I've got an eight inch line and I'm crossing a 36 inch line? Again, that, that variable would be farther down on my list of variables that impact overall magnitude of interference. Pipeline diameter definitely does play into the overall interference.
Smaller diameter pipelines generally experience a little bit more interference as opposed to large diameter lines. So that diameter does play into it. Yeah, interesting. So great kind of explanation of the of the problem and its complexity.
What do you do to mitigate these impacts? Because I mean, fundamentally, what we're trying to do is mitigate metal loss due to how we're conducting that electricity, right? So what do you do to mitigate all this? Yeah, there's there's several techniques that we can utilize to reduce AC interference.
They are all the different types of grounding. We want to ground the pipeline in some sort of way at specific locations that is going to safely remove the alternating current from the pipeline. If this alternating current is discharging into the soil through the coating, it's going to result in accelerated corrosion. And that's similar to your discussions on CP when current is leaving metal, brings metal with it causes corrosion.
We want to provide a safe path for that current to travel to ground. So I'll start off with probably the most commonly utilized method for AC mitigation. And that is the installation of a parallel grounding cable or sometimes it's called a gradient control wire. Basically, it's a copper or zinc ribbon cable that we would bury at pipeline depth or close to it.
It could be as close as one foot or maybe it's separated by upwards of 10 feet. And what it's doing is it's going to become that sacrificial cable. So rather than current discharging from the pipeline coating into the soil, the current is going to see that low resistance copper or zinc and it's going to look for the path of least resistance. It's going to prefer to flow onto the copper or zinc and then it'll discharge into the soil from there.
So that copper or zinc will corrode in preference to the pipeline. And that is the most probably the most common and effective method. In terms of fault interference, I mentioned earlier when when power line faults occur and there's large currents dumped into the earth, these same cables can provide shielding from those harmful currents. So you have a current traveling towards your pipeline instead of being directly, you know, directly flowing onto your pipeline.
It'll see this low resistance cable that you've strategically situated between your pipeline and the interfering source. And that cable will help to absorb that current. There's a few other techniques as well. So what is the most elegant?
The most elegant of all these techniques would be this parallel grounding cable. It has the ability to mitigate steady state, eight sea interference and also provide that fault shielding. Other techniques we use, they are very effective. Some of both the steady state and fault scenario, but some are less effective at mitigating fault because of the inability to position these cables in such a way where they're in between your pipeline and the interfering source.
Right. And I guess you also have to maintain those cables, right? Yeah, they do have a sacrificial. They're going to, you know, once once they're gone, then, you know, you have nothing there to protect you.
Right. Yeah, they do have a finite life and someday they will corrode. Similar to cathodic protection systems and anodes, it's approximately 20 plus years of life you would get out of these systems. And there's ways we can measure the performance of the system and determine if maybe it's time to replace the cable or add more grounding.
But yeah, you're absolutely right. So how does how does this affect your cathodic protection? How does this AC affect your cathodic protection systems? Because I would assume that what you're doing for cathodic protection within the magnetic field is different than what you're doing outside of it.
Right. And at the at the areas of transition would be they would require special handling. I guess it'd be the way to say that. Right.
And that's a topic that still up for debate. We have a lot to learn about the exact interactions between cathodic protection and AC interference, but we do have a pretty good idea of what is going on. So a lot of studies have shown that the presence of AC interference could effectively depolarize your pipeline cathodic protection levels. You'll bring bring them down so you would be receiving less protection.
So the natural thing to do would be to turn them up. However, other studies show that excessive cathodic protection could lead to accelerated AC corrosion. And it has to do with the chemical reactions that are occurring at the steel and soil interface. We have changes in pH going on and changes in solar resistivity and all of these variables effectively either raise or lower magnitude of interference.
And so the general consensus is that you want to find a sweet spot with your cathodic protection levels. You don't want to be under protected. You don't want to be over protected. So take a look.
I think this is one of the reasons why people with lots of years of field experience in this domain, even more so than some others is really important. Right. Because there's a fair amount of this that goes to local knowledge too, because particularly soils and drainage affect this a lot. Yeah, soils are one of the biggest variables when looking at AC interference, specifically soil resistivity and the environment that the pipeline is in.
If you have a very low resistance soil exterior to the pipeline coating, it's going to be very easy for that current to discharge into the soil. So your current densities are going to go up and your corrosion rates are going to increase. On the other hand, if you had a very high resistance soil exterior to the coating, it's not as easy of a path for that current to travel into. So more of that current is going to be retained by the pipeline and it's going to make your voltage go up, which is a safety concern.
So that soil resistivity, it's so important to note and it really is a double edged sword with how it impacts both current density and AC voltage. Right. Well, it's like a lot of the things all easy to know enough about it. Right.
Right. And you know, it's very important if you're ever, you know, you're trying to measure the impacts of AC interference on your pipeline and something that would always go along with that would be the collection of solar resistivity measurements, because that is one of those variables that's just very difficult to assume and an incorrect assumption there could severely underestimate what your pipeline is actually experiencing. Right. And you could have solar resistivity varying drastically over a pipeline route.
You know, you've got pre crossings and river crossings where there's low resistance or rocky areas with higher resistance. So it's very important to know the environment your pipeline is in. So, Frank, what would you say that every pipeline or should know about AC and AC effects and mitigation? How would you boil this whole conversation down?
It's a phenomenon that is not cut and dry and it's very difficult to look at a pipeline route and just come up with a solution for mitigating a senior fairance or sometimes you may not even be able to determine if your pipeline is going to experience interference or not. So it's important if your pipeline is in close proximity, not to make an assumption and skip the analysis that could really determine if your personnel is going to be exposed to shot hazards or if your pipeline is going to be exposed to accelerated corrosion. Right. Well, listen, this has been great.
I feel more intelligent than I did when we started this conversation. So I thank you. Absolutely. Thanks for having me.
I hope you enjoyed this week's episode of the Pipelineers Podcast on a Conversation with Frank Nesto. Just a reminder before you go, you should register to win our customized Pipelineers Podcast Yeti Tumblr. Simply visit pipelineerspodcast.com slash win and enter yourself in the drawing. If you'd like to support this podcast, best way to do that is leave us review.
You can do that on iTunes, Apple Podcast, Google Play, whatever smart device you happen to use. If you have ideas, questions or topics you'd be interested in, please let me know on the contact us page at pipelineerspodcast.com or reach out to me on LinkedIn. Thanks for listening. I'll talk to you next week.