Low Ambient, Condenser Flooding, and Headmaster Valves

from HVAC School - For Techs, By Techs

In this podcast episode, Jeremy Smith comes on the podcast to talk about low-ambient controls, headmaster valves, charging, and condenser flooding. If our head pressure drops too much, we won't get enough of a pressure drop across the TXV. Pressures dictate the TXV function, so we need to make sure our systems give that valve what it needs to operate correctly. Three pressures operate a TXV: bulb pressure, spring pressure, and evaporator pressure. However, pressures throughout the system can also affect the pressures that act on a TXV. Condensers are sized for maximum heat rejection at the highest ambient temperatures a unit will experience. Low-ambient controls help get your liquid pressure up by effectively reducing the condenser's capacity. One common thing we can do is use a fan cycle; a pressure control can turn the fan on and off, but you can see large pressure swings. We can also use headmasters, which maintain head pressure by backing up liquid in the condenser; it fills the condenser with liquid and shifts some discharge gas to the receiver to maintain the receiver pressure. Headmasters are NOT adjustable in the field. When diagnosing headmasters, try to look for leaks first; Jeremy thinks many headmaster failures could have been misdiagnosed. Split condensers can shut off parts of themselves to reduce capacity, which can serve as another low-ambient control without bypassing discharge gas or wasting energy. You may also come across some adjustable controls that allow you to adjust your head pressure by setting receiver pressure and other similar values. Jeremy and Bryan also discuss: Balanced-port TXVs Fan cycling in air conditioning Using a clear sight glass to charge refrigeration units Headmaster part numbers Carrier Motormasters Parallel rack systems and remote condensers Inefficiency and bypassing discharge gas Read the companion tech tip HERE. If you have an iPhone, subscribe to the podcast HERE, and if you have an Android phone, subscribe HERE.

Episode details come from the podcast's RSS feed.

Embed this episode

Ready to play

Low Ambient, Condenser Flooding, and Headmaster Valves

0:00 36:11

No transcript yet.

Requests help us decide what to transcribe next.

Frequently asked questions

How long is this episode of HVAC School - For Techs, By Techs?

This episode is 36 minutes long.

When was this HVAC School - For Techs, By Techs episode published?

This episode was published on February 3, 2017.

Can I download this HVAC School - For Techs, By Techs episode?

Yes. Use the download control on the episode player to save the publisher-provided media file.