Recent Updates and Upgrades to ASHRAE SSPC 52.2 episode artwork

EPISODE · Apr 29, 2024 · 21 MIN

Recent Updates and Upgrades to ASHRAE SSPC 52.2

from Talking Air Filtration · host National Air Filtration Association

Recent Updates and Upgrades to ASHRAE SSPC 52.2 - SSPC 52.2 has made many updates and upgrades over the last few years to improve the standard. Many of those updates are meant to increase the repeatability and reproducibility of intra and inter-lab test results. Recent upgrades include an optional method to determine filter efficiency in removing or inactivating airborne viruses and bacteria. The addition of a Particulate Matter (PM) calculated filter efficiency by using currently available data points from the 52.2 test. This session will summarize in detail all the updates and upgrades and touch on what is next for 52.2. View the slides from Mr. McGrath's presentation: https://amped.egnyte.com/dl/ACqyqKb6fQ For detailed show notes, read below and use the timestamps to navigate the episode: [1:50] Mr. McGrath begins the overview of recent 52.2 upgrades in the last five years with the MERV Table for better progressions and shedding data for testing filters. He then moves on to updates for relative humidity and narrowing down the range of percentages. For the optical particle counter, updates were more terminology-related.   [5:11] Mr. McGrath explains the goal of repeatability and reproducibility with graphs outlining how filters are tested for efficiency across different labs. Improvement should revolve around the grouping of data points for the particle diameter.   [5:43] Mr. McGrath introduces the most recent project, Research Project 1784, in which samples were filtered across multiple labs to determine whether lab testing standards vary. These results will assess changes in ASHRAE standard 52.2.   [7:37] Mr. McGrath examines the removal of MERV 17 and what led to that reference removal, as well as MERV 18, 19 and 20 references.   [10:04] Recent Upgrades to 52.2 in the last year or two, including the addition of PM 52.2 filter efficiency based on a flat distribution curve and using E-values.   [13:31] The recent COVID-19 pandemic led to changes in ASHRAE 52.2 Addendum C, which helps collect filter efficiency data for viruses and bacteria. Calculations were created to determine the presence of the organism and its ability to grow. Variety in organisms detected is still needed due to organism resistance.   [17:00] Mr. McGrath concludes with current 52.2 pursuits that revolve around unifying terminology for testing and parameters for checking devices. Research project 1784 is ongoing, and its results will lead to new upgrading projects.

Episode metadata supplied by the publisher feed · Published Apr 29, 2024

Embed this episode

NOW PLAYING

Recent Updates and Upgrades to ASHRAE SSPC 52.2

0:00 21:34

No transcript for this episode yet

We transcribe on demand. Request one and we'll notify you when it's ready — usually under 10 minutes.

No similar episodes found.

No similar podcasts found.

Frequently Asked Questions

How long is this episode of Talking Air Filtration?

This episode is 21 minutes long.

When was this Talking Air Filtration episode published?

This episode was published on April 29, 2024.

Can I download this Talking Air Filtration episode?

Yes. Use the download control on the episode player to save the publisher-provided media file.
URL copied to clipboard!