Short #38 - Low Ambient Cooling

from HVAC School - For Techs, By Techs

This short podcast episode covers the why and the how of low ambient cooling and refrigeration. Low ambient cooling refers to operating A/C equipment during low outdoor ambient conditions. Typically, the cap of operation is around 55 or 60 degrees. However, some commercial facilities need cooling when the outdoor temperature is cold. For example, those facilities may have to cool electronics or large volumes of people. In buildings that don't have economizers, running the A/C in cold ambient conditions may be the only option. The same applies to restaurants, which always need to run freezers and coolers. When the outdoor ambient temperature drops, the condenser rejects more heat to the outdoors. Head pressure drops, and there may be an insufficient pressure drop across the metering device. We also can't run A/C evaporator coils below 32 degrees, as there is no defrost mechanism in straight-cool A/C systems. So, the strategy to get around those issues is to focus on raising the head pressure by modulating the condenser fan motor. A fan cycling control can turn the condenser fan on and off based on pressure. So, we try to maintain a fixed pressure in the condenser by allowing that control to shut off the fan when the pressure drops too much. However, fan cycling can be a bit jarring for the system. Motor master controls help modulate the motor by decreasing voltage to the motor. However, that fluctuating voltage isn't necessarily good for the motor. In those cases, you must have a ball-bearing motor. Unlike the motor master, a refrigeration headmaster is a valve that allows discharge gas to enter the drop leg. Variable frequency drives can work with a three-phase motor to vary the speed of the motor. When the speed can vary easily, you can manipulate the pressure. Learn more about Refrigeration Technologies HERE. If you have an iPhone, subscribe to the podcast HERE, and if you have an Android phone, subscribe HERE.

Episode details come from the podcast's RSS feed.

Embed this episode

Ready to play

Short #38 - Low Ambient Cooling

0:00 16:47

No transcript yet.

Requests help us decide what to transcribe next.

Frequently asked questions

How long is this episode of HVAC School - For Techs, By Techs?

This episode is 16 minutes long.

When was this HVAC School - For Techs, By Techs episode published?

This episode was published on January 22, 2019.

Can I download this HVAC School - For Techs, By Techs episode?

Yes. Use the download control on the episode player to save the publisher-provided media file.