MN Journeyman Sprinkler Fitter Exam Prep

by CaseyJames669

This podcast will focus on the required reference material needed for the MN Journeyman Sprinkler Fitter Exam.

From the show's RSS feed, refreshed Aug 24, 2025. Source feed.

Subscribe Bookmark

Episodes

  1. NFPA 13 Special Situations: Shafts, Stairways, Elevators, Vertical Openings & Stages | MN Journeyman Exam Prep

    NFPA 13 Special Situations: Shafts, Stairways, Elevators, Vertical Openings & Stages | MN Journeyman Exam Prep NFPA 13 special situations: shafts, stairways, elevators, vertical openings, draft stops, ducts, stages, and skylights. The main Minnesota event is 7511.0903 903.3.1.6.2 — sprinklers…

    more
  2. NFPA 13 Allowable Sprinkler Omissions: Concealed Spaces, Closets, Electrical Rooms, Canopies & Cloud Ceilings | MN Journeyman Exam Prep

    NFPA 13 Allowable Sprinkler Omissions: Concealed Spaces, Closets, Electrical Rooms, Canopies & Cloud Ceilings | MN Journeyman Exam Prep Allowable sprinkler omissions in NFPA 13: the concealed-space exception list, bathrooms, closets, electrical rooms, canopies and exterior projections, and cloud...

  3. Freeze Protection for Wet Sprinkler Systems: 40°F Rule, Heat Tracing, Dry Sprinklers & Heated Valve Rooms | MN Journeyman Exam Prep

    Freeze protection for wet systems: the 40 degree rule, every allowed alternate (antifreeze or listed systems, insulation or casings holding 40 to 120, listed and supervised heat tracing, PE heat-loss calcs), dry sprinkler barrel lengths from Table 15.3.1(a), heated valve rooms, freezer piping...

  4. NFPA 13 System Acceptance: Hydrostatic Tests, Air Tests, Flushing & Test Certificates | MN Journeyman Exam Prep

    System acceptance: hydrostatic testing at 200 psi or 50 over working pressure for 2 hours, the dry-system 40 psi air test for 24 hours with 1.5 psi allowed loss, underground flushing flow rates at 10 ft/s, blank tracking, alarm and dry-trip tests, and the Contractor's Material and Test…

    more
  5. NFPA 25 Weekly & Monthly ITM: Control Valves, Gauges, Dry & Preaction Valves, Fire Pumps & Cold-Weather Checks | MN Journeyman Exam Prep

    NFPA 25 weekly and monthly inspections: the control valve ladder (sealed weekly, locked/supervised monthly), backflow and RPZ checks, dry and preaction valve enclosures and compressors, gauges, fire pump weekly/monthly items, cold-weather daily checks, and the Minnesota fire code's 901.6.1...

  6. NFPA 13 ESFR Sprinklers: Installation, Spacing, Deflector Distances & Obstructions | MN Journeyman Exam Prep

    ESFR installation: 100 sq ft maximum and 64 sq ft minimum per sprinkler, 12/10 ft spacing, 8 ft minimum, 30 ft ceiling and 25 ft storage limits, roof slope, deflector distances by K-factor, the obstruction table, draft curtains, and 36 in. clearance to storage. Design pressures (Chapter 23) are…

    more
  7. NFPA 13 Test Connections & Pressure Gauges: Inspector's Test, Trip Test Manifolds & Gauge Rules | MN Journeyman Exam Prep

    Inspector's test connections, trip test manifolds, and pressure gauges. Wet-system test connection anywhere downstream with the smallest K-factor, dry-system test at the far end with brass fittings, the 15 s and 60 s water-delivery rules, gauge locations, quarter-inch gauge valves,...

  8. NFPA 13 Drainage: Main Drains, Auxiliary Drains, Pipe Pitch & Drain Sizing | MN Journeyman Exam Prep

    Drainage: main drains, auxiliary drains, and pipe pitch. Half-inch and quarter-inch per 10 ft, everything half-inch in refrigerated areas, the drain sizing table (3/4, 1-1/4, 2 in.), auxiliary drain tiers by trapped gallons, drum drips, drain discharge, the 4 ft of heated pipe rule, and NFPA 25...

  9. NFPA 13 Control Valves: Listed Indicating Valves, PIVs, Check Valves & Supervision | MN Journeyman Exam Prep

    Control valves: listed indicating valves, PIVs and wall PIVs, check valves, and the four ways to supervise a valve. We cover valve location and accessibility, no shutoff in the FDC line, valves on both sides of a check, PRVs at 175/165 psi with the half-inch relief, PIV height of 32 to 40 inches...

  10. Hydraulics for the MN Exam: Hazen-Williams, C-Factors, Friction Loss & Equivalent Length | MN Journeyman Exam Prep

    The Hazen-Williams formula in plain English, the C-factor table (100, 120, 140, 150), why the fitting table is "C = 120 only" and how the multipliers work, equivalent lengths for elbows, tees, and valves, what's in and out of the calc, feet of head vs. psi, and K = Q/√P with worked examples....

  11. NFPA 13 High-Piled Storage & Commodity Classification: Classes, Arrays & Ceiling Sprinklers | MN Journeyman Exam Prep

    Class I through IV, Group A/B/C plastics, cartoned vs. exposed, the 5/15 and 5/25/40 percentage rules, plastic pallets, open vs. closed arrays, rack types, flues, mixed commodities, and the general information sign. Minnesota adopts NFPA 13-2016, so we flag the 2016 numbers alongside 2019. Plus a...

  12. NFPA 13 Water Supplies: Duration, Hose Stream Allowances & Pressure Requirements | MN Journeyman Exam Prep

    Is there enough water, for long enough? At least one automatic supply, what counts as a supply, the 6-inch private main rule, pressure tanks, a live two-hydrant flow test (static, residual, measure the outlet), 0.433 psi per foot and 2.31 feet per psi, then the two evil-twin tables: hydraulically...

  13. NFPA 13 Wet Pipe Systems: Alarm Check Valves, Retard Chambers & Waterflow Alarms | MN Journeyman Exam Prep

    The plain-Jane system nobody studies. How an alarm check valve and retard chamber actually work (and why a plugged retard drain makes the outside bell ring like a drunk church), gauges above and below the check, the relief valve "175 psi or 10 over, whichever is greater," the...

  14. NFPA 13 Obstructions to Spray Patterns: Continuous, Noncontinuous & Shadow Areas | MN Journeyman Exam Prep

    Eighteen inches below the deflector splits the whole chapter. Above it, the spray pattern's still developing: the three times rule (24-inch cap, but not for columns), "structural members only" in light and ordinary hazard, straddling obstructions up to 4 ft, trusses, the beam table, wall soffits,...

  15. NFPA 13 Hangers & Supports: Spacing, Rod Sizes & Fasteners (Non-Seismic) | MN Journeyman Exam Prep

    Holding the pipe up, no sway bracing. Five times water-filled plus 250 lb vs. what the building has to carry, listed vs. unlisted parts, rod and U-hook sizes, fasteners in concrete, steel and wood (powder-driven 750/1000/1200 lb), toggles, metal deck, trapezes, the max-spacing table for steel,...

  16. NFPA 13 Sprinkler Spacing & Protection Area: Light, Ordinary & Extra Hazard | MN Journeyman Exam Prep

    How far apart, how far off the wall, and how much floor one standard spray head is allowed to cover. We walk the S x L method, the light/ordinary/extra hazard and storage tables (that cursed 168 sq ft row), the 225 vs. 400 sq ft caps, four-inch and six-foot minimums, baffles, small rooms, angled...

  17. NFPA 2001 Clean Agents & MSFC 904.10: Design Concentration, Discharge Time, Hold Time & Inspections | MN Journeyman Exam Prep

    Clean agent systems: NFPA 2001 and Minnesota 904.10. Halocarbons vs. inert gases, safety factors, the 10-second discharge, the 85%/10-minute hold, abort vs. manual release, and the six-month container check with the Minnesota tag. The usual: two fitters, a lot of swearing (18+), a lightning round...

  18. NFPA 72 & MSFC 903.4 Sprinkler Supervision: Waterflow, Tamper, Supervisory Signals & Exterior Alarms | MN Journeyman Exam Prep

    The alarm side of sprinklers: NFPA 72 and Minnesota 903.4. Waterflow in 90 seconds, tamper switches in two turns, supervisory pressure, level and temperature numbers, test frequencies, and exactly what Minnesota says must be supervised. The usual: two fitters, a lot of swearing (18+), a lightning...

  19. NFPA 20 Fire Pumps & MSFC 913: Suction, Relief Valves, Pump Rooms & Acceptance Tests | MN Journeyman Exam Prep

    Fire pumps, NFPA 20 and Minnesota 913. Suction rules that keep pumps alive (zero psi at 150%, OS&Y only within 50 feet, ten pipe diameters, eccentric reducers), circulation and pressure relief valves, pump room protection, and the acceptance test. The usual: two fitters, a lot of swearing (18+)…

    more
  20. NFPA 14 Standpipes & MSFC 905: Classes, Pressures, Flows & Minnesota Hose Connections | MN Journeyman Exam Prep

    Standpipes, NFPA 14 and Minnesota 905. Classes I, II and III, wet vs. dry vs. manual vs. semiautomatic, pressure limits and PRVs, flow rates, and Minnesota's own modification for non-high-rise buildings. The usual: two fitters, a lot of swearing (18+), a lightning round of exam tips, and a war...

  21. NFPA 10 Portable Fire Extinguishers: Ratings, Placement, Inspection & Hydro | MN Journeyman Exam Prep

    Halloween special: portable fire extinguishers. Ratings, placement and travel distance, monthly inspections, annual maintenance, and hydro intervals under NFPA 10 and MSFC 906. The usual: two fitters, a lot of swearing (18+), a lightning round of exam tips, and a war story that is mostly true....

  22. NFPA 24 Underground Mains: Bury Depth, Thrust Restraint, Flushing & Hydro | MN Journeyman Exam Prep

    Underground private fire service mains: bury depth, thrust blocks and restraint, flushing flows, and the hydro test. Everything that goes in the dirt before the riser. The usual: two fitters, a lot of swearing (18+), a lightning round of exam tips, and a war story that is mostly true. Minnesota…

    more
  23. NFPA 22 Water Tanks: Heating, Suction Tanks, Vortex Plates & Levels | MN Journeyman Exam Prep

    Water tanks for fire protection, the NFPA 22 way. We dig into tank heating and the 40-degree rule, suction tanks, vortex plates, and the level and temperature supervision numbers that show up on the Minnesota journeyman exam. The usual: two fitters, a lot of swearing (18+), a lightning round of...

  24. Seismic Protection: Flex Couplings, Clearance, Sway Bracing & Restraint | MN Journeyman Exam Prep

    Seismic protection for sprinkler piping, for the Minnesota journeyman sprinkler fitter exam. Minnesota pins NFPA 13-2016, where this is section 9.3. NFPA 13-2019 moved it to Chapter 18. The big numbers are the same in both editions, and we flag what 2019 added. Whether a building needs seismic...

  25. NFPA 13R Low-Rise Residential | MN Journeyman Exam Prep

    NFPA 13R, sprinklers for low-rise residential buildings (apartments, hotels, dorms, board and care), for the Minnesota journeyman sprinkler fitter exam. Every number comes from NFPA 13R-2016, the newest edition we could verify. Check newer editions if your exam uses them. When Minnesota allows…

    more
  26. NFPA 13D One- & Two-Family Dwellings | MN Journeyman Exam Prep

    NFPA 13D, sprinklers for one- and two-family dwellings and manufactured homes, for the Minnesota journeyman sprinkler fitter exam. Minnesota pins 13D-2016 (Minn. R. 7511.8000); we map it to 13D-2019. When Minnesota requires house sprinklers (MSFC 903.2.8: R-3 dwelling units of 4,500 sq ft and up,...

  27. Sprinkler Identification, Temperature Ratings & Spare Sprinklers | MN Journeyman Exam Prep

    Sprinkler identification, temperature ratings and spare sprinklers for the Minnesota journeyman sprinkler fitter exam. NFPA 13 (2016 6.2/8.3, the edition Minnesota pins, mapped to 2019 7.2, 9.4.2 and 16.2) plus NFPA 25-2020: only new sprinklers, no reinstalling (except dry per manufacturer), no...

  28. Occupancy Hazard Classification & Design Density | MN Journeyman Exam Prep

    Occupancy hazard classification and what it does to your design, for the Minnesota journeyman sprinkler fitter exam. NFPA 13 (2016 ch.5/11, the edition Minnesota pins, mapped to 2019 ch.4/19): classifications are for sprinkler design only; light hazard, ordinary group 1 (8 ft stockpiles)…

    more
  29. Pipe, Fittings & Joining Methods | MN Journeyman Exam Prep

    Pipe, fittings and joining methods, every rule a Minnesota journeyman sprinkler fitter needs for the exam. NFPA 13 (2016 chapter 6, the edition Minnesota pins, mapped to 2019 chapters 7 and 16, with 2025 checks): the pipe standards table (ASTM A795, F442 CPVC, lead-free solder, BCuP-3/4 brazing...

  30. Antifreeze Systems | MN Journeyman Exam Prep

    Antifreeze sprinkler systems, every rule a Minnesota journeyman sprinkler fitter needs for the exam. NFPA 13 (2016 section 7.6, the edition Minnesota pins, side by side with 2019 section 8.6, with 2025 checks): state and local health regulations, ESFR only with a listed head (premixed propylene...

  31. Dry Pipe & Preaction Systems | MN Journeyman Exam Prep

    Dry pipe and preaction systems (plus a little deluge), every rule a Minnesota journeyman sprinkler fitter needs for the exam. NFPA 13 (2016, the edition Minnesota pins, side by side with 2019, with 2025 checks): where dry systems belong, Minnesota's flammable-liquid storage rule (wet, deluge or...

  32. Fire Department Connections | MN Journeyman Exam Prep

    Fire department connections, every rule a Minnesota journeyman sprinkler fitter needs for the exam. Minnesota State Fire Code 2020 Section 912: location approved by the fire code official, street-side visibility, the existing-building FDC locator sign (6 in. letters, 2 in. words), Minnesota's 18...

  33. Kitchen Hoods & Alternative Extinguishing Systems | MN Journeyman Exam Prep

    Minnesota State Fire Code 2020 Section 904, the systems that aren't sprinklers but land on a sprinkler fitter's plate anyway. Minnesota's amended 904.1.1 service-personnel certificate, why an alternative system can't be used to claim sprinkler trade-offs, Type I hood protection, actuation,...

  34. Listener Prep Sheet: Deflectors, Obstructions, Sidewalls, Drains, Hangers & ITM | MN Journeyman Exam Prep

    A listener handed us his LICENSING EXAM - PREP QUESTIONS study sheet, and we go through every line of it with the books open. NFPA 13 deflector position and how to measure below flat and sagging batt insulation; obstructed vs. unobstructed construction and the concrete tee rule, which picked up a...

  35. Limited Area Sprinklers, Quick Response & Water Supplies | MN Journeyman Exam Prep

    The installation rules in Minnesota State Fire Code 2020 Section 903.3 that nobody reads until an inspector reads them to you. Where quick-response or residential sprinklers are mandatory, the four-foot kiosk rule and the three-foot clearance over combustible fiber piles, automatic actuation…

    more
  36. Joining the Sprinkler Fitter Union in Minnesota | MN Journeyman Exam Prep

    How you actually get into the sprinkler fitter union in Minnesota, read off the sources, not off barstool rumors. Sprinkler Fitters Local 417 (chartered 1903) covers Anoka, Dakota, Hennepin, Ramsey, Scott and Washington counties out of the hall at 529 County Rd E in Shoreview. The once-a-year,...

  37. Apprentice Questions Answered | MN Journeyman Exam Prep

    Every question Minnesota sprinkler apprentices ask, answered from Minn. Stat. 299M, Minn. R. 7512 and the State Fire Marshal's exam booklet: who qualifies for the journeyman exam, why it's closed book and your construction calculator stays home, the 70% pass mark, retest waits, conditional...

  38. Take a Number, Asshole — Who the AHJ Is in Minnesota, Permits, Surcharges and City Permit Programs

    Who's actually the authority having jurisdiction for a sprinkler job in Minnesota, the city or the state, and what that means for your permit, your cost estimate, the .012 state permit fee and the .002 surcharge. We also dig into what Minn. Stat. 299M.07 and Minn. R. 7512.2800 require of cities...

  39. Put the Fucking Tile Back — Minnesota's Ceiling Rules and Existing-Building Sprinkler Amendments

    Minnesota added its own ceiling rules in 7511.0901 (IFC 901.11): ceiling tiles stay in place, open-grid ceilings don't go under sprinklers unless NFPA 13 is met, and drop-out ceilings only when every NFPA 13 requirement is met. Then we get into Minnesota's rewrite of the existing-building chapter...

  40. Bonus: Annual, 3-Year and 5-Year Inspections — What You Actually Fucking Do (NFPA 25 + Minnesota's Annual Rollup)

    Two fitters walk through what actually gets inspected, tested and maintained on a sprinkler system every year, every 3 years and every 5 years under NFPA 25 (2017 edition): main drains, dry pipe trip tests, gauges, waterflow devices and the 5-year internal pipe assessment. Then the Minnesota…

    more
  41. Minnesota Fucked With Your Standard — 7511.8000 and the State's Amendments to NFPA 13, 13R, and 13D

    Minnesota doesn't just adopt NFPA 13, 13R, and 13D. It pins the editions in Minn. R. 7511.8000 and rewrites pieces of them through the fire code: linen closets, FDC check valves, 36-month flow tests, vestibules, elevator shafts where heads are flat-out banned, pool ceilings, townhouse garage dry...

  42. Bonus: Who the Fuck Shut the Valve? — Impairments, Tags, and Fire Watch When the System's Out of Service

    When a sprinkler system goes out of service in Minnesota, the fire code doesn't give you a grace period. It says notify the fire department and the fire code official immediately. We go line by line through MSFC 901.7 (the impairment coordinator, the five tag locations, the eight-step preplanned...

  43. Bonus: We Fucked Up — Red-Tagging Our Own Cheat Sheet Episode

    Our Cheat Sheet bonus taught you some rules the 2025 NFPA 13 and 2026 NFPA 25 already changed, so we're red-tagging our own work on air. ESFR slope, the dead CMSA concrete tee rule, the new 30-inch stem cap, the 25 percent dry pipe trigger, the five-point internal exam, and doorless closets, all...

  44. Bonus: Casey's Cheat Sheet — Fifteen Scribbled Study Notes, Fact-Checked Against the Actual Book

    Casey fed a page of his own exam notes through the scanner, so we went line by line against NFPA 13, 13R, 13D, NFPA 25, the JATC math book, and Minnesota's amendments. Some notes are dead on. Some will get you fucked on the Minnesota exam, like elevator pit heads that Minnesota flat-out bans and…

    more
  45. Where Minnesota Says Sprinkle It — 7511.0903 Triggers, Thresholds, and the 5 PSI Tax

    Minnesota rewrote big chunks of IFC Section 903, including Group E, Group R, S-1 storage, exhaust ducts, undetermined-use buildings, and a 5 psi water supply safety margin nobody outside this state has heard of. We go through every amended threshold in Minn. R. 7511.0903 and the exact wording…

    more
  46. Inspect My Ass — Who's Legally Allowed to Touch a Minnesota Sprinkler System

    A deep dive into the scope and exceptions of Minn. R. 7512 and Minn. Stat. 299M — what "fire protection-related work" means for a contractor versus a fitter, the surprisingly narrow definition of "inspect," the A-through-G contractor license exceptions, the "maintain" and emergency-impairment...

  47. Pulled Card, Red Tag, Fat Fine — Suspension, Revocation, Civil Penalties and Cease-and-Desist in Minnesota

    The disciplinary end of Minn. R. 7512 and Minn. Stat. 299M, start to finish — what gets your license or card revoked, the 7/14/28-day suspension ladder and its floors, what "willfully" really means, the $1,000-per-violation-per-day civil penalty, and the working-day clock on a cease-and-desist...

  48. Card or Get the Fuck Off the Lift — Journeyman, Conditional, Limited Certs and Apprentices in Minnesota

    Two fitters tear through Minn. R. 7512 and Minn. Stat. 299M on who's actually allowed to touch a sprinkler system in Minnesota, from the 8,000-hour exam ticket to the six-month conditional card, the premises-only limited card, June 30 renewals, and the three-part direct supervision test for...

  49. Impairments and obstruction investigations

    Impairments, red tags, and obstruction investigations when the system’s dirty or compromised. Flashcard scenarios plus the paperwork reality.Season 3 · Ep 3MN exam editions we stick to: NFPA 13/20 family 2016, NFPA 25 2017, MSFC 2020. Study talk, not the code book - if this fights your booklet…

    more
  50. Main drain, waterflow, and weekly tests

    Main drain tests, waterflow alarms, and the weekly/monthly grind. We pull the questions from the study deck and talk through pass/fail the way the exam words it.Season 3 · Ep 2Built from real MN journeyman exam flashcards: we hit the question, the correct answer, why the wrong ones fail, then how...

About this show

This podcast will focus on the required reference material needed for the MN Journeyman Sprinkler Fitter Exam.

Hosted by

CaseyJames669

Categories

Frequently asked questions

How many episodes does MN Journeyman Sprinkler Fitter Exam Prep have?

MN Journeyman Sprinkler Fitter Exam Prep has 128 episodes on PodParley. The most recent episode was published on November 20, 2026.

What is MN Journeyman Sprinkler Fitter Exam Prep about?

This podcast will focus on the required reference material needed for the MN Journeyman Sprinkler Fitter Exam.

How often does MN Journeyman Sprinkler Fitter Exam Prep release new episodes?

MN Journeyman Sprinkler Fitter Exam Prep publishes weekly, based on its 128 episodes since October 2024.

Who hosts MN Journeyman Sprinkler Fitter Exam Prep?

MN Journeyman Sprinkler Fitter Exam Prep is created and hosted by CaseyJames669.