All episodes
NFPA 13 Special Situations: Shafts, Stairways, Elevators, Vertical Openings & Stages | MN Journeyman Exam Prep
ENFPA 13 Allowable Sprinkler Omissions: Concealed Spaces, Closets, Electrical Rooms, Canopies & Cloud Ceilings | MN Journeyman Exam Prep
EFreeze Protection for Wet Sprinkler Systems: 40°F Rule, Heat Tracing, Dry Sprinklers & Heated Valve Rooms | MN Journeyman Exam Prep
ENFPA 13 System Acceptance: Hydrostatic Tests, Air Tests, Flushing & Test Certificates | MN Journeyman Exam Prep
ENFPA 25 Weekly & Monthly ITM: Control Valves, Gauges, Dry & Preaction Valves, Fire Pumps & Cold-Weather Checks | MN Journeyman Exam Prep
ENFPA 13 ESFR Sprinklers: Installation, Spacing, Deflector Distances & Obstructions | MN Journeyman Exam Prep
ENFPA 13 Test Connections & Pressure Gauges: Inspector's Test, Trip Test Manifolds & Gauge Rules | MN Journeyman Exam Prep
ENFPA 13 Drainage: Main Drains, Auxiliary Drains, Pipe Pitch & Drain Sizing | MN Journeyman Exam Prep
ENFPA 13 Control Valves: Listed Indicating Valves, PIVs, Check Valves & Supervision | MN Journeyman Exam Prep
EHydraulics for the MN Exam: Hazen-Williams, C-Factors, Friction Loss & Equivalent Length | MN Journeyman Exam Prep
ENFPA 13 High-Piled Storage & Commodity Classification: Classes, Arrays & Ceiling Sprinklers | MN Journeyman Exam Prep
ENFPA 13 Water Supplies: Duration, Hose Stream Allowances & Pressure Requirements | MN Journeyman Exam Prep
ENFPA 13 Wet Pipe Systems: Alarm Check Valves, Retard Chambers & Waterflow Alarms | MN Journeyman Exam Prep
ENFPA 13 Obstructions to Spray Patterns: Continuous, Noncontinuous & Shadow Areas | MN Journeyman Exam Prep
ENFPA 13 Hangers & Supports: Spacing, Rod Sizes & Fasteners (Non-Seismic) | MN Journeyman Exam Prep
ENFPA 13 Sprinkler Spacing & Protection Area: Light, Ordinary & Extra Hazard | MN Journeyman Exam Prep
ENFPA 2001 Clean Agents & MSFC 904.10: Design Concentration, Discharge Time, Hold Time & Inspections | MN Journeyman Exam Prep
ENFPA 72 & MSFC 903.4 Sprinkler Supervision: Waterflow, Tamper, Supervisory Signals & Exterior Alarms | MN Journeyman Exam Prep
ENFPA 20 Fire Pumps & MSFC 913: Suction, Relief Valves, Pump Rooms & Acceptance Tests | MN Journeyman Exam Prep
ENFPA 14 Standpipes & MSFC 905: Classes, Pressures, Flows & Minnesota Hose Connections | MN Journeyman Exam Prep
ENFPA 10 Portable Fire Extinguishers: Ratings, Placement, Inspection & Hydro | MN Journeyman Exam Prep
ENFPA 24 Underground Mains: Bury Depth, Thrust Restraint, Flushing & Hydro | MN Journeyman Exam Prep
ENFPA 22 Water Tanks: Heating, Suction Tanks, Vortex Plates & Levels | MN Journeyman Exam Prep
ESeismic Protection: Flex Couplings, Clearance, Sway Bracing & Restraint | MN Journeyman Exam Prep
ENFPA 13R Low-Rise Residential | MN Journeyman Exam Prep
ENFPA 13D One- & Two-Family Dwellings | MN Journeyman Exam Prep
ESprinkler Identification, Temperature Ratings & Spare Sprinklers | MN Journeyman Exam Prep
EOccupancy Hazard Classification & Design Density | MN Journeyman Exam Prep
EPipe, Fittings & Joining Methods | MN Journeyman Exam Prep
EAntifreeze Systems | MN Journeyman Exam Prep
EDry Pipe & Preaction Systems | MN Journeyman Exam Prep
EFire Department Connections | MN Journeyman Exam Prep
EKitchen Hoods & Alternative Extinguishing Systems | MN Journeyman Exam Prep
EListener Prep Sheet: Deflectors, Obstructions, Sidewalls, Drains, Hangers & ITM | MN Journeyman Exam Prep
ELimited Area Sprinklers, Quick Response & Water Supplies | MN Journeyman Exam Prep
EJoining the Sprinkler Fitter Union in Minnesota | MN Journeyman Exam Prep
EApprentice Questions Answered | MN Journeyman Exam Prep
ETake a Number, Asshole — Who the AHJ Is in Minnesota, Permits, Surcharges and City Permit Programs
EPut the Fucking Tile Back — Minnesota's Ceiling Rules and Existing-Building Sprinkler Amendments
EBonus: Annual, 3-Year and 5-Year Inspections — What You Actually Fucking Do (NFPA 25 + Minnesota's Annual Rollup)
EMinnesota Fucked With Your Standard — 7511.8000 and the State's Amendments to NFPA 13, 13R, and 13D
EBonus: Who the Fuck Shut the Valve? — Impairments, Tags, and Fire Watch When the System's Out of Service
EBonus: We Fucked Up — Red-Tagging Our Own Cheat Sheet Episode
EBonus: Casey's Cheat Sheet — Fifteen Scribbled Study Notes, Fact-Checked Against the Actual Book
EWhere Minnesota Says Sprinkle It — 7511.0903 Triggers, Thresholds, and the 5 PSI Tax
EInspect My Ass — Who's Legally Allowed to Touch a Minnesota Sprinkler System
EPulled Card, Red Tag, Fat Fine — Suspension, Revocation, Civil Penalties and Cease-and-Desist in Minnesota
ECard or Get the Fuck Off the Lift — Journeyman, Conditional, Limited Certs and Apprentices in Minnesota
EImpairments and obstruction investigations
Main drain, waterflow, and weekly tests
Suction, diesel, and the relief valve stuff
Layout questions that wreck people on the exam
Reading prints without looking lost
Design density and acceptance testing
Seismic bracing — the boring stuff that shows up
13D / 13R and the small room rule
Storage, commodity class, and ESFR (don't wing it)
MN Exam Deep Dive — Pumps (Grounded)
MN Exam Deep Dive - Standpipe (Grounded)
MN Exam Deep Dive — Safety (Grounded)
MN Exam Deep Dive — Underground (Grounded)
MN Exam Deep Dive — Standpipe (Grounded)
MN Exam Deep Dive — Mn Law (Grounded)
MN Exam Deep Dive — Itm (Grounded)
MN Exam Deep Dive — Installation (Grounded)
MN Exam Deep Dive — Pumps (Grounded)
Standard Spray Upright and Pendent Sprinklers — Ceiling Clearance, Storage Separation, and Structural Beam Obstructions (The "3-Times Rule")
Obstructions Installed Entirely Below Sprinklers (The 4-Foot Rule for Overhead Ducts, Decks, and Trays)
Dry Pipe Valve Trip Testing Frequencies, Water Delivery Recording, and Internal Inspections
We're going to Fargo! For a dry system of course...
Air Venting for Wet Pipe Sprinkler Systems – NFPA 13 (2016), Sections 7.1.5 and 8.16.6 (adopted via MN State Fire Code 2020).
EPipe Hanger Spacing and Installation Requirements for Sprinkler Systems
EWhen Fire Sprinklers Become Flamethrowers
NFPA vs MN
Crack the Code
Minnesota Journeyman Sprinkler Fitter Exam: Deep Dive
Grok 4 Expert to the Test - The Deep Dive: Fire Protection Systems
Quizlet0325_Corrected_DeDuped_Refined_By_Overlord_AI
Episode 10: Training and Being Less of a Dumbass
Episode 9: Human F*cking Relations
Episode 8: Fire Alarms: No Screwing Around (NFPA 72)
Episode 7: ITM: Don't Be A Dumbass (NFPA 25)
Episode 6: Standpipes and F*cking Mains (NFPA 14 and 24)
Episode 5: Sprinklers 101 (NFPA 13, 13D, and 13R)
Episode 4: Clean Agent: How To Actually Use It
Episode 3: Clean Agent Bullshit (NFPA 2001)
Episode 2: Egress: Don't Get F*cked in a Fire
Episode 1: NFPA Shitshow
Episode 25: Quizlet Material - Putting it All Together
Episode 24: Training and Continuous Improvement
Episode 23: Human Relations - How to Not Be an Asshole
Episode 22: Hydraulics - Water Pressure Under Control
Episode 21: Special Application Sprinkler Systems
Episode 20: Types of Fire Protection Systems
Episode 19: Blueprint Reading - Part 2: Matchlines, Pipe Runs, and Fire Hose Stations
Episode 18: Blueprint Reading - Part 1: Orthographic, Isometric, Flow Charts
Episode 17: Architectural Drawings - Seeing the Big Picture
Episode 16: Math Skills - Numbers That Matter
Episode 15: NFPA 72 - Part 2: Voice Systems and Documentation
Episode 14: NFPA 72 - Part 1: Fire Alarm Systems and Components